Cleanliness of the cleanroom is generally expressed in the number of particles contained in the unit volume of air. Therefore, the smaller the numbers of the cleanliness class, the higher the grade (less dust) of the cleanroom. For the standard of cleanliness, the U. S. Federal Standards (FS-209D E) were used generally but has been abolished when ISO14644 has been enacted (2000). However, the cleanliness class based on FS 209D is still widely used in actual cleanrooms. This expresses the fine-particulate concentration as the number of particles in 1 cubic foot (pieces/ft3). Although the standard particle size is 0.5 μm in the FS-209D standard.
Sandwich panel Is popular today The general structure consists of sheet metal such as METAL SHEET sprayed and baked with EPOXY paint or STAINLESS Sheet # 304. To be compressed or injected with Poly Urethane foam or Poly Styrene. Enter the center to increase strength And is thermal insulation With thickness from 2 “, 3”, 4 “KNOCKDOWN installation which is convenient, fast and easy to move, popularly used with CLEANROOM at all levels, CLASS and suitable for CLEANROOM with wet and corrosive chemicals
GYPSUM wall is plastered, smooth, polished and painted with EPOXY paint, installed with GALVANIZE STEEL frame, economical as an alternative for CLEANROOM ISO.-CLASS 7, 8 (CLASS 10K, 100K) but must be CLEANROOM without damp CONCRETE wall is smooth and coated with EPOXY paint, popular with CLEANROOM that is wet or has corrosive chemicals. Installation and demolition difficult to move Is an alternative for CLEANROOM ISO-CLASS 7, 8 (CLASS 10K, 100K) as well
The air conditioning system of the room CLEANROOM requires this equipment. To act as an air carrier to reduce the temperature And through the air filter (AIR FILTER) And air circulation By absorbing air with particles, pollutants in the room that are filtered at various types of air filters (Including cooling from the coil, cooling COIL, choosing to use both the type of water heat exchanger and heat exchanger with the refrigerant) before paying back to the room
AIR DUCT is an air duct device There are both round and square forms. Depending on the installation area, use GALVANIZE STEEL material wrapped in PE. CLOSE CELL insulation. Assemble with various types of FITTING.
Use STAINLESS # 304 sheet material for high-humidity CLEANROOM. Or contain corrosive chemicals